Products

Products

+
  • 主图_001(1741671608803).webp
  • 主图_002(1741671608799).webp
  • 主图_003(1741671608819).webp
  • 主图_004(1741671608872).webp
  • 主图_005(1741671608815).webp

Customizable 1ml Adjustable Pipette for Medical Equipment Use

Product model:

Pipette


product details


Pipette is widely used in today's society.Pipette is very comfortable to use,And it's more humanized. Compared to measuring cylinders, handling hazardous chemicals is safer.Pipette pole It is accurate and can be accurately  measured  when  transporting  solutions.  Pipette  saves time Improve the efficiency of laboratory work. The multi-channel  Pipette is a high-precision Ideal for high efficiency and repeatability. It can be used for various liquids, including foam liquid Body, high Vapor pressure liquid and high viscosity liquid. Refine the brand's newly upgraded LUCKY series Pipette is divided into single channel, 8-channel and 12 channel multi-function Pipette. Design with Ergonomic, with a wider range from a minimum of 0.1ul to a maximum of 10ml,and higher accuracy With reliable  features, it can better meet the diverse  application  needs of  modern  laboratories. Impact  resistance  Resistant  to  UV and chemical corrosion,better  able  to  meet  long-term stable  liquid  transfer  work, and  the  nozzle  The components are made of specific materials and can be disassembled to support high-temperature and high-pressure sterilization, as well as independent range calibrationAnd so on.

 

ingle-channel parameter list

Product number

Specification

Increment

Test
volume(μL)

Maximum allowable error
Inaccuracy(%)

Maximum allowable error
Imprecision(%)

23010100002

0.1~2.5μL

0.05μL

2.5μL

±2.50%

2.00%

1.5μL

±3.00%

3.00%

0.25μL

±12.00%

6.00%

23010100010

0.5~10μL

0.1μL

10μL

±1.00%

0.80%

5μL

±1.50%

1.50%

1μL

±2.50%

1.50%

23010100020

2~20μL

0.5μL

20μL

±0.90%

0.40%

10μL

±1.20%

1.00%

2μL

±3.00%

2.00%

23010100050

5~50μL

0.5μL

50μL

±0.60%

0.30%

25μL

±0.90%

0.60%

5μL

±2.00%

2.00%

23010100100

10~100μL

1.0μL

100μL

±0.80%

0.20%

50μL

±1.00%

0.40%

10μL

±3.00%

1.00%

23010100200

20~200μL

1.0μL

200μL

±0.60%

0.20%

100μL

±0.80%

0.30%

20μL

±2.50%

0.80%

23010101000

100~1000μL

5.0μL

1000μL

±0.60%

0.20%

500μL

±0.70%

0.25%

100μL

±2.00%

0.70%

23010105000

1000~5000μL

50.0μL

5000μL

±0.50%

0.20%

2500μL

±0.60%

0.30%

1000μL

±0.70%

0.30%

23010110000

1000~10000μL

100μL

10000μL

±0.60%

0.20%

5000μL

±1.20%

0.30%

1000μL

±3.00%

0.60%

 

Pipette operation
A. Set the range*The display window of the handle can clearly display the pipette amount. The amount of pipette is set by turning the operating buttonclockwise or counterclockwise (only for adjustable pipettes).When setting the range, please note: Rotate to the desired range The numbers are clearly displayed in the display window, The measuringrange is within the range of pipette. Do not screw the button out of range,Otherwise it will jam the mechanism and damage the pipette.
B. Pipetting technique
Forward pipetting:
Make sure the pipette tip is tightly attached to the tip cone. Move the action button slowly and evenly for optimal pipetting, especiallywhen transferring viscous liquids.
Keep the pipette vertica when aspirating.At the same time, ensure that the specimen liquid and solution tank are clean, and the pipette,suction head, and liquid temperature are the same.
1) Press the operation button to the first stop point.2) Plunge the suction head into the liquid level 2-3 m m, gently release the operation button (back to the origin). Carefuly lift the suctionhead away from the liquid level and place it on the container wall to remove excess liquid.3) Tap the button to the first stop point, and the liquid willbe discharged. Pause for a moment and continue to press the operation buttonto the second stop point (i.e. blow out). This step will empty the suction head and ensure accurate fluid transfer.4) Release the button and return to the starting point.
3. Storage
* If the pipette is not in use, it is recommended to hang it vertically on the pipette rack.


8-channel parameter list

Product number

Specification

Increment

Test
volume(μL)

Maximum allowable error
Inaccuracy(%)

Maximum allowable error
Imprecision(%)

23010800010

0.5-10μL

0.1μL

10μL

±1.50%

1.50%

5μL

±2.50%

2.50%

1μL

±4.00%

4.00%

23010800050

5-50μL

0.5μL

50μL

±1.00%

0.50%

25μL

±1.50%

1.00%

5μL

±3.00%

2.00%

230108000300

50-300μL

5μL

300μL

±0.70%

0.25%

150μL

±1.00%

0.50%

50μL

±1.50%

0.80%

 

 

12-channel parameter list

Product number

Specification

Increment

Test
volume(μL)

Maximum allowable error
Inaccuracy(%)

Maximum allowable error
Imprecision(%)

23011200010

0.5-10μL

0.1μL

10μL

±1.50%

1.50%

5μL

±2.50%

2.50%

1μL

±4.00%

4.00%

23011200050

5-50μL

0.5μL

50μL

±1.00%

0.50%

25μL

±1.50%

1.00%

5μL

±3.00%

2.00%

23011200300

50-300μL

5μL

300μL

±0.70%

0.25%

150μL

±1.00%

0.50%

50μL

±1.50%

0.80%

Product Message

For suggestions or feedback, please submit your information, and we will contact you promptly, or call us directly.

%{tishi_zhanwei}%