Products
product details
It is an economical dry bath incubator controlled by a microprocessor, using high-purity aluminum as the thermal conductive medium to replace traditional water baths. It features elegant appearance, easy operation, high accuracy, and compact size. It can be widely used for sample preservation and reactions, DNA amplification and pre-denaturation for electrophoresis, serum coagulation, etc.
Automatic fault detection and buzzer alarm function, temperature deviation calibration function, real-time temperature and countdown display, elegant appearance, blue LCD display of real-time parameter information.
Multiple safety protections ensure long-term operational stability and safety under unattended conditions, complying with CE standards.
Supports module-specific custom calibration function, built-in over-temperature protection device.
Real-time temperature and countdown display.
| Parameter | Value |
| Model | L-100 |
| Temperature Setting Range | -10℃~100℃ |
| Temperature Control Range | Ambient temperature minus 30℃~100℃ |
| Time Setting | 1min ~ 99h59min/∞ |
| Temperature Control Accuracy | ≤±0.3℃* |
| Display Accuracy | 0.1℃ |
| Temperature Uniformity | ≤±0.3℃* |
| Heating Time | ≤12 minutes (25℃ to 100℃)* |
| Cooling Time 1 | ≤10 minutes (100℃ to 25℃)* |
| Cooling Time 2 | ≤25 minutes (room temperature to ambient minus 30℃)* |
| Multi-point Operation | Supported (max 5 points) |
| Multi-point Cycle Operation | Supported (max 99 cycles) |
| Automatic Preheating | Supported |
| Auto-start on Power-on | Supported |
| Automatic Recovery after Power Failure | Supported |
| Sample Capacity | See module selection table |
| Input Power | 150W |
| Voltage | AC220V/50-60Hz |
| Fuse | 250V 3A Φ5×20 |
| Dimensions | 260×195×150 mm |
| Weight | 4.5Kg |

Product parameters
Microcomputer controlled cooling metal bath
| Model number | L-100 |
| Temperature setting range | -10°C~100°C |
| Temperature control range | Below room temperature 30°C~100°C |
| Time setting | 1min ~ 99h59min/∞ |
| Temperature control accuracy | ≤±0.3°C* |
| Accuracy of display | 0.1°C |
| Uniformity of temperature | ≤±0.3°C* |
| Heating up time | ≤12minutes (25°C至100°C) * |
| Cooling time1 | ≤10minutes (100°C至25°C) * |
| Cooling time2 | ≤25minutes (Room temperature to below room temperature30°C) * |
| Multi-point operation | Support (Maximum 5 points) |
| Multi-point loop operation | Support (The maximum number of cycles is 99 times) |
| Automatic preheating | Support |
| Start automatic operation | Support |
| Automatic recovery of power failure | Support |
| Volume of sample | See the module selection table |
| Input power | 150W |
| voltage | AC220V/50-60HZ |
| Fuse breaker | 250V 3A Φ5×20 |
| Size | 260x195x150 mm |
| weight | 4.5Kg |
| Module model | Number of tubes and pore size |
|---|---|
| L30 | 96×0.2ml (standard edition) |
| L31 | 54×0.5ml (centrifuge tube) |
| L32 | 35×1.5ml (Centrifuge tube) |
| L33 | 35×2.0ml (centrifuge tube) |
| L34 | 15×0.5ml+20×1.5ml (centrifuge tube) |
| L35 | 96×0.2ml (microplate) |
| L36 | 24×5ml (centrifuge tube) |
| L37 | 15×10ml (centrifuge tube) |
| L38 | 12×15ml (centrifuge tube) |
| L39 | 6×50ml (50ml round bottom centrifuge tube) |
| L39-S | 6×50ml (50ml conical bottom centrifuge tube) |




Product parameters
Microcomputer controlled cooling metal bath
| CH-100 (Heating up) | CL-100 (refrigeration) | |
|---|---|---|
| Type of equipment | - | - |
| Module Specification | CHSeries module | CLSeries module |
| Temperature setting range | 0°C~100°C | -10°C~100°C |
| Temperature control range | Room temperature+5°C~100°C | Below room temperature 25°C~100°C |
| Time setting | 1sec~99h59min/∞ | 1sec~99h59min/∞ |
| Temperature control accuracy (37°C when) | ≤±0.3°C | ≤±0.3°C |
| Accuracy of display | 0.1°C | 0.1°C |
| Uniformity of temperature (37°C when) | ≤±0.3°C | ≤±0.3°C |
| Heating up time | ≤12minutes(25°C~100°C) | ≤12 minutes (25°C~100°C) |
| Heating up time1 | / | ≤12 minutes (100°C~25°C) |
| Heating up time2 | / | ≤25 min (room temperature drops to 25°C below room temperature) |
| Hot cover temperature setting range | OFF~+10°C | OFF~+10°C |
| Heat cover temperature control accuracy | ≤±0.5°C | ≤±0.5°C |
| Heat cover heating time | ≤10minutes(25°C~100°C) | ≤10 minutes (25°C~100°C) |
| The samples were stored at 4°C at the end of operation | Support | Support |
| Multi-point operation | Support (Maximum 5 points) | Support (Maximum 5 points) |
| Multi-point loop operation | Support (The maximum number of cycles is 99) | Support (The maximum number of cycles is 99) |
| Automatic preheating | Support | Support |
| Start automatic operation | Support | Support |
| Automatic recovery of power failure | Support | Support |
| Volume of sample | See module selection table | See module selection table |
| Input power | 150W | 150W |
| voltage | AC220V/50-60HZ | AC220V/50-60HZ |
| Fuse breaker | 250V 3A Φ5×20 | 250V 3A Φ5×20 |
| Dimensions of appearance | 300×200×210mm | 300×200×210mm |
| weight | 4.0 Kg | 4.0 Kg |
| Model of module | Sample size | Temperature control range |
|---|---|---|
| CL-01 | 35 x 2.0mL Centrifuge tube | RT-25°C~100°C |
| CL-02 | 35 x 1.5mL Centrifuge tube | RT-25°C~100°C |
| CL-03 | 54 x 0.5mLCentrifuge tube | RT-25°C~100°C |
| CL-04 | 96 x 0.2mL PCRStandard plate | RT-25°C~100°C |
| CL-05 | 96 x 0.2mL Enzyme labeled plate | RT-25°C~100°C |
| CH-06 | 35 x 2.0mL Centrifuge tube | RT+5°C~100°C |
| CH-07 | 35 x 1.5mL Centrifuge tube | RT+5°C~100°C |
| CH-08 | 54 x 0.5mLCentrifuge tube | RT+5°C~100°C |
| CH-09 | 96 x 0.2mL PCRStandard plate | RT+5°C~100°C |
| CH-10 | 96 x 0.2mL Enzyme labeled plate | RT+5°C~100°C |




Product Message
For suggestions or feedback, please submit your information, and we will contact you promptly, or call us directly.
Manager Ren
+86 18221726865
elaine@shqiujing.com.cn
Building 4, Lane 455, Zhuting Road, Yexie Biomedical Industrial Park, Songjiang District, Shanghai
Follow official account